Web(a) Each transmission line, other than offshore segments, must have sectionalizing block valves spaced as follows, unless in a particular case the Administrator finds that alternative spacing would provide an equivalent level of safety: (1) Each point on the pipeline in a Class 4 location must be within 2 1/2 miles (4 kilometers)of a valve. (2) Each point on the … WebDec 16, 1996 · §192.5 Class Locations • (b) Except as provided in paragraph (c) of this section, pipeline locations are classified as follows: – (1) A Class 1 location is: • (i) An …
Class location 192
Did you know?
WebClass 1 –Any location within 220 yards of either side of a 1 mile length of a pipeline containing 10 or fewer dwellings. Class 2 –Any location within 220 yards of either … Web§192.5 Class locations. (a) This section classifies pipeline lo-cations for purposes of this part. The following criteria apply to classifica-tions under this section. (1) A ‘‘class location unit’’ is an on-shore area that extends 220 yards (200
Web§ 192.609: Change in class location: Required study. § 192.610: Change in class location: Change in valve spacing. § 192.611: Change in class location: Confirmation or revision of maximum allowable operating pressure. § 192.612: Underwater inspection and reburial of pipelines in the Gulf of Mexico and its inlets. § 192.613: Continuing ...
WebA Class location unit is an onshore area that extends "220 yards (200 meters) on either side of the centerline of any continuous 1- mile (1.6 kilometers) length of pipeline (Title 49 § 192.5, Transportation of Natural and Other Gas by Pipeline: Minimum Safety Standards). http://cdmcs.org/wp-content/uploads/2024/01/Federal-Requirements-for-Gas-Pipelines.pdf
WebPART 192 - TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Subpart L - Operations § 192.619 …
WebClass 3, or 4 location Area 2. An area within a Class 2 location the operator determines by using any of the following three methods: (a) A Class 2 location; (b) An area extending 150 feet (45.7 m) on each side of the centerline of any continuous 1 mile (1.6 km) of pipeline and including more than 10 but fewer than 46 dwellings; or instant specialty coffee packetsWebReduce pressure, as necessary, and limit MAOP to no greater than the highest actual operating pressure sustained by the pipeline during the 5 years preceding October 1, 2024, divided by the greater of 1.25 or the applicable class location factor in § 192.619 (a) (2) (ii). jj\u0027s pressure washingWebAug 1, 2013 · Part 192 Regulations Impacted by Class Location. There are indirect or secondary links to class location throughout Part 192. These links include sections that … instant speech maker freeWeb( a) The present class location for the segment involved. ( b) The design, construction, and testing procedures followed in the original construction, and a comparison of these … jj\\u0027s redcliffe opening hoursWeb( 1) A Class 3 or Class 4 location; or ( 2) A moderate consequence area as defined in § 192.3, if the pipeline segment can accommodate inspection by means of an … jj\u0027s scaffolding ltdWeb(1) A Class 4 location ends 220 yards (200 meters) from the nearest building with four or more stories above ground. (2) When a cluster of buildings intended for human … jj\u0027s sandwich shop castleford menuWebeCFR :: 49 CFR 192.611 -- Change in class location: Confirmation or revision of maximum allowable operating pressure. The Electronic Code of Federal Regulations Title 49 Displaying title 49, up to date as of 3/08/2024. Title 49 was last amended 3/06/2024. view historical versions Title 49 Subtitle B Chapter I Subchapter D Part 192 Subpart L instant speech recognition